Sensors and Transducers
Mass Air Flow Sensors
Automotive MAF Modules
Pirani Vacuum Sensors
 
 

POSIFA Microsystems Inc

1925 Zanker Road,
San Jose, CA 95112
USA
Tel: 1-650-646-5788
Fax: 1-866-213-8603
Email: info@posifamicrosystems.com

  

European Distributor

BS-rep GmbH
Eichertstr. 68, D-56745 Weibern, Germany

Tel: +49 (0) 2655 / 96 26 476
Email: info@sensor-rep.de 

  

  

 

PMF2000 (10 to 2000 sccm)

The PMF2000 series of Mass Air Flow Sensors covers the ranges from 10 sccm to 2000 sccm for both unidirectional and bidirectional flow. The sensors are fully calibrated and compensated over the temperature range of 0 to 50 °C (32 to 122 °F). The linearized analog output (1 to 5 V) provides maximum flexibility and ease-of-use.  Accuracy is 2% full scale.


PMF2000 Series Datasheet

Part Number Spec Price
PMF2050V

1 to 5 V, linear; 0 to 10 SCCM

Quote
PMF2100V

1 to 5 V, linear; 0 to 30 SCCM

Quote
PMF2101V

1 to 5 V, linear; 0 to 200 SCCM

Quote
PMF2102V

1 to 5 V, linear; 0 to 1000 SCCM

Quote
PMF2103V

1 to 5 V, linear; 0 to 2000 SCCM

Quote
  • Features
  • Applications
  • Specs
  • Resources
  • Unsurpassed performance in a robust and cost effective package
  • High accuracy and repeatability (1.5% F.S.)
  • Linear output and temperature compensation
  • Long-term stability with minimal null drift
  • "Solid state" sensing core (no surface cavity or fragile membrane), resistant to clogging and pressure shock
  • Analog output (1 to 5 V)
  • High sensitivity at very low flows
  • Fast response time (1 ms)
  • Bidirectional flow sensing option
  • Medical respirators and ventilators
  • Patient monitoring systems
  • Anesthesia delivery machines
  • Nebulizers
  • Oxygen concentrators
  • Sleep apnea machines
  • Ventricular assistance devices
  • Environmental monitoring
  • Analytical instrumentation
  • Gas leak detection
  • Filter monitoring and VAV systems in HVAC
  • Process Control
ELECTRICAL CHARACTERISTICS
Test Conditions: Vin=10±0.01VDC, Ta=25°C. Relative Humidity: 40%<RH<60%
Maximum Operating Temperature Range –25°C to +85°C
PARAMETERS PMF2050V   CONDITIONS
MIN TYP MAX UNIT
Flow Range1 (Full Scale) 0   10 SCCM  
Max Output Voltage  4.95 5.00   5.05 VDC  @10 sccm 
PARAMETERS PMF2100V   CONDITIONS
MIN TYP MAX UNIT
Flow Range1 (Full Scale) 0   30 SCCM  
Max Output Voltage  4.95 5.00   5.05 VDC  @30 sccm 
PARAMETERS PMF2101V   CONDITIONS
MIN TYP MAX UNIT
Flow Range1 (Full Scale) 0   200 SCCM  
Max Output Voltage  4.95 5.00   5.05 VDC  @200 sccm 
PARAMETERS PMF2102V   CONDITIONS
MIN TYP MAX UNIT
Flow Range1 (Full Scale)  0   1000 SCCM  
Max Output Voltage  4.95  5.00  5.05 VDC  @1000 sccm 
PARAMETERS PMF2103V   CONDITIONS
MIN TYP MAX UNIT
Flow Range1 (Full Scale)  0   2000 SCCM  
Max Output Voltage  4.95  5.00  5.05 VDC  @2000 sccm 
PARAMETERS PMF2000 Series   CONDITIONS
MIN TYP MAX UNIT
Analog Voltage Output 2 1   5 VDC  
Null Voltage  .95 1 1.05  VDC  
Null Drift   0.2   % / Year  Full Scale
Temperature Drift     4 %  0°C to +50°C
Repeatability    0.1   %  Full Scale
Load   100    
Accuracy (Full Scale)   1.5   %  
Linearity Error (Full Scale)     0.8 %  
Response Time   1 mSec  
Supply Voltage 8 10 14 VDC  
Supply Current 22   23 mA  
Wetted Materials Silicon carbide, Epoxy, PPS, FR4, Silicone as static seal
1. Custom ranges available between 10 and 2000 sccm
2. See Linear Output Flow Rate Calculation on Page 3
 